| Heaters
|
| 150,000 Diesel Fired Heater
|
|
|
This tough, dependable, high output unit, rated a hefty
150,000 BTU/hr, wheels right to the spot you selected. The built-in
thermostat quickly warms up your coldest areas. Every hour, every day, the
economical choice in all kinds of industrial, commercial and agriculture
environments. Heats up to 3,500 sq. ft. (50' x 70' x 8')
|
|
|
|
| CODE 3836 |
| DAY |
$ 40.00 |
| WEEK |
$ 140.00 |
| MONTH |
$ 400.00 |
|
| Specifications |
| Capacity - BTU's/Hour |
150,000 |
| Maximum hours of continuous
operation* |
15/19* |
| Fuel tank capacity (gallons) |
16.5 |
| Net weight (less fuel) lbs. |
105 |
| Size in inches |
44x20x37 |
| *
With Thermostat |
|
HOW TO FIND THE RIGHT SIZE HEATER FOR YOUR
WORKSPACE
First, determine the cubic feet of the area you will heat.
Use the formula: Length X Width X Height. For example 28' X 25' X 10' = 7,000
cu. ft.
Next, decide the typical heat rise you'll require. For example, if the room temperature,
unheated drops to 15 degrees F and you want it heated to 70 degrees F, the heat
rise requirement is 70 degrees minus 15 degrees = 55 degrees.
Then use this formula: (sample numbers inserted) 7,000 cu. ft. X 0.133
(constant) X 55 degrees (temperature rise) = 51,205 BTU per hour required.
|
|